about CCTV system please help me?

all about nothing!!!! asked:


desigened a system for contronl two buildings qu? monkeys (field water) these two buildings far from each other and want to connect the c? maras site (CCTV system) in the far building to the main building (main control room ) without any wires qu? m? everything I used (the system of radio, microwave, GSM or any other m? all) (the distance butween the nearly 3 kil? meters)

Share and Enjoy:
  • Digg
  • Sphinn
  • del.icio.us
  • Facebook
  • Mixx
  • Google

Tags: , ,

3 Responses to “about CCTV system please help me?”

  1. Dave D Says:

    Because of the bandwidth and distance involved, a microwave link is your only realistic option. A radio system with enough power would never be licensed, and a laser system would not have the range without using expensive telescopes. Continuous operation would be far too expensive in GSM, even if it were permitted. Fiber optic would also work, but then you would have to run the cable. No problems with lightening, though.

  2. more slack Says:

    If both buildings are on a network, an IP camera would be simpler since it can use the existing IP infrastructure. If no infrastructure is available, then an IP cam can be bridged onto 802.11g which can achieve that kind of line-of-sight range. Links below are prepackaged solutions for this.

    If you don’t have line-of-sight then EV/DO or UMTS 3G cellular might be feasible if the recurring cost isn’t a problem.

  3. mankurak Says:

    in general, CCTV can connected wireless, there more choice to connect them. for radio system and microwave each another building could see with visual and GSM is there any networking supporting (Base Transceiver Station/BTS)
    You don’t give where your location or map for studying the best choice…

Leave a Reply

Bookmarks
    500 Internal Server Error

    Internal Server Error

    The server encountered an internal error or misconfiguration and was unable to complete your request.

    Please contact the server administrator, webmaster@eonserver.getsn.com and inform them of the time the error occurred, and anything you might have done that may have caused the error.

    More information about this error may be available in the server error log.

    Additionally, a 500 Internal Server Error error was encountered while trying to use an ErrorDocument to handle the request.


    Apache mod_auth_passthrough/2.1 mod_bwlimited/1.4 FrontPage/5.0.2.2635 Server at eonserver.com Port 80